We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for High-frequency circuit analysis tools.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

High-frequency circuit analysis tools - List of Manufacturers, Suppliers, Companies and Products

High-frequency circuit analysis tools Product List

1~2 item / All 2 items

Displayed results

High-frequency circuit analysis tool

[Application Examples] Application Materials for High-Frequency Passive Probes / MP300

【Product Introduction】 ■High-Frequency Passive Probe MP300 A passive probe with low input capacitance and a wide frequency range. The MP300 is a passive probe that features low input capacitance and a wide frequency range. It is used by connecting to measuring instruments (such as spectrum analyzers and oscilloscopes) with an input impedance of 50Ω. The input resistance of the MP300 is 500Ω, resulting in an attenuation ratio of 10:1. This value is significantly lower than that of typical passive probes or FET probes, so care must be taken regarding the impact on the circuit under test in the DC to low-frequency range. However, due to its low input capacitance and input impedance being close to a pure resistance, the load effect is minimal in the high-frequency range, allowing for better frequency response. It is ideal for comparing simulation results during high-frequency circuit design and for failure analysis.

  • Printed Circuit Board

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

High-frequency circuit analysis tool

[Application Example] Suitable for circuit analysis in high-frequency circuit design.

The "MP300" is a passive probe with low input capacitance and a wide frequency range. It is used by connecting it to a measuring instrument with an input impedance of 50Ω. With an input resistance of 500Ω, the attenuation ratio is 10:1, which is significantly lower than that of typical passive probes or FET probes, so care must be taken regarding the impact on the circuit under test in the DC to low-frequency range. However, due to its low input capacitance and input impedance being close to a pure resistance, the load effect is small in the high-frequency range, resulting in better frequency response. It is suitable for comparison with simulation results during high-frequency circuit design and for failure analysis. 【Product Introduction】 ■ High-frequency passive probe "MP300" - Low input capacitance with a wide frequency range *For more details, please refer to the PDF document or feel free to contact us.